Architecture and versions
The original HYC400 supports 100, 200, 300 and 400 kW configurations with up to four 100 kW Power-Stacks. The manufacturer specifies 50 kW allocation granularity. Do not confuse the original HYC400 with Series 2: documentation differs and the quoted generation must be confirmed.
The original specification lists 500 A continuous and 600 A boost, depending on configuration. A 400 V vehicle limited to 500 A cannot receive more than 200 kW even with spare modules. At 800 V and 500 A the electrical ceiling is 400 kW, provided vehicle and equipment sustain it.
Example DC allocation, subject to voltage, current and configuration. Not a physical electronics drawing.
When two vehicles charge
If two vehicles request 250 kW each, demand totals 500 kW, above the 400 kW total. A hypothetical allocation of 200 + 200 kW fits the limit. If one accepts only 100 kW, up to 300 kW may remain for the other, subject to current, cabling, firmware and actual allocation strategy.
The rating is DC output. A 400 kW AC supply is not equivalent to continuous 400 kW DC: losses and auxiliary loads exist. The manufacturer states efficiency up to 97.5%; do not treat that as constant efficiency for an entire session.
Integration and continuity
Original documentation lists OCPP 1.6 J and readiness for 2.0 J. Series 2 lists 2.0.1 J; confirm the supplied firmware version and profiles, including power management, metering and offline behaviour. OCPP alone does not guarantee that a platform controls every function.
For fleets, shared cabinet availability is critical. Compare two independent units (less common-mode exposure) or central power with dispensers (greater bay flexibility). Kempower and ABB are alternatives to investigate by architecture and configuration, not direct equivalents. Request layout, simultaneous limits, support and response times.