1. Identify what happened
Start with session records: connection time, transaction start, metered energy and end reason. Verify the connector belongs to the correct vehicle. If there is no session, check connection, authorisation and scheduling per the manual. If a session has 0 kWh, check states and power limits. If energy was insufficient, compare duration, average power and target.
In OCPP 1.6, SuspendedEV indicates a vehicle-side suspension and SuspendedEVSE a station-side suspension. These can be intentional pauses, not faults, e.g. an SOC limit or power sharing. OCPP 2.0.1 communicates charging state differently; check version and full history. An isolated state does not establish root cause.
Use logs and current SOC to separate diagnosis from dispatch decisions.
2. Decide whether it can leave
Calculate current battery energy from usable capacity, SOH and SOC. Subtract the required arrival reserve. If remaining energy does not cover the mission, quantify the shortfall before charging, reassigning a vehicle or modifying the route. The example below excludes en-route charging.
If SOC is unknown, get a recent reading before dispatch. A 10 kWh battery shortfall requires more than 10 grid kWh. At 11 grid kW and 90% efficiency, at least 61 minutes are needed if vehicle and station sustain that power.
Check departure readiness
- Current usable capacity
- 71.3 kWh
- Minimum departure SOC
- 66.1 %
- Energy-only minimum SOH
- 147.1 %
- Minimum additional charge time
- 78.1 min
Energy criterion using initial usable capacity and capacity SOH; no safety, power or warranty assessment. Minimum SOC above 100% means charging alone cannot solve it.
Technical result (JSON)
{
"schemaVersion": 1,
"tool": "incident",
"inputs": {
"battery": 75,
"energy": 36.4,
"soh": 95,
"soc": 48,
"reserve": 15,
"power": 11
},
"defaultedInputs": [],
"results": {
"capacity": 71.25,
"available": 23.5125,
"gap": -12.8875,
"minimumSoh": 147.07070707070707,
"minimumSoc": 66.08771929824562,
"required": 36.4,
"recoverable": 23.5125,
"minutes": 78.1060606060606,
"feasible": 0
},
"assumptions": {
"efficiencyPct": 90,
"designMarginPct": 15,
"model": "aggregate energy bounds; no individual schedule or vehicle certification",
"vending": "incremental rolling resistance only; peak and mean loads separate",
"battery": "capacity-based SOH; energy criterion only; no safety or warranty assessment"
},
"documentation": "https://www.autonality.ai/ai/fleet-intelligence.md"
}3. Prevent recurrence
Configure alerts for missing sessions after expected start, cumulative energy below the required trajectory and inadequate SOC before departure. An offline charger alert helps but is not sufficient: some stations can continue charging without a backend connection. Record actual cause and compare final SOC with target.
For damage, burning smell, abnormal heat or electrical warnings, follow manufacturer and site safety procedures. Do not open equipment or bypass protections. For recurring faults, give maintenance IDs, timestamps, states, energy and available logs. Replanning departure and resolving the technical cause are different tasks.