Architecture and vehicle choice
Mercedes-Benz Trucks installs three lithium iron phosphate (LFP) packs rated at 207 kWh nominal each. This cathode chemistry uses neither nickel nor cobalt. Nominal capacity is not automatically the energy usable between BMS limits, so we do not present 600 kWh as verified usable capacity.
The eActros 400, with two packs and 414 kWh nominal, is an alternative if routes need less energy. Less battery can leave more payload allowance. For comparison with MAN eTGX, Volvo FH Electric or Renault Trucks E-Tech T, request exact tractor tare, trailer mass and charge curves.
Installed nominal capacity, not usable capacity. Architecture diagram, not physical pack location.
Estimating heavy-duty route energy
A 14 t payload does not mean a 14 t combination. Add tractor, trailer and equipment. Rolling resistance, aerodynamics, gradient and downhill recovery all affect consumption. A test’s kWh/100 km therefore cannot be transferred automatically to another duty cycle.
Engineering example, not an eActros consumption claim: 300 km at 120 kWh/100 km needs 360 battery kWh. With a 15% reserve and 90% departure SOC, at least 480 usable kWh are needed today. At 90% SOH, initial usable capacity would need to be 533.3 kWh. This helps frame an OEM data request, not certify a route.
CCS, MCS and operational stops
The specified CCS2 peak is 400 kW. Average power will be lower if battery, voltage, cable current or site capacity limit the process. Recovering 360 battery kWh in 45 minutes requires 480 kW average into the battery, above the published CCS peak. Finding a 400 kW charger is not enough.