A configurable battery
The eDaily uses 37 kWh packs, up to four for 148 installed kWh in compatible configurations. Not all wheelbases and gross weights allow every pack count. This differs from vans built around two fixed battery sizes. The aim of modularity is not maximising kWh but matching energy, weight and acquisition cost to the actual service the vehicle must perform.
Installed energy by pack count
Availability depends on chassis and variant.
A panel van is not a converted chassis
Iveco offers panel van and chassis-cab versions up to 7.2 t GVW. A tail lift, refrigerated box or crane needs mass allowance and sometimes auxiliary electrical energy. Choose wheelbase and axle limits with the bodybuilder: the capacity of a bare chassis is not the cargo allowance of the completed vehicle.
How to size the pack count
Imagine a 120 km route at 30 kWh/100 km plus 8 kWh for equipment. Total demand is 44 kWh. With a 75% SOC window and 90% SOH you need 65.2 initial usable kWh. One 37 kWh installed pack can never suffice under those conditions. Two packs totalling 74 kWh could fit if confirmed usable capacity exceeds that threshold.
Confirm AC and DC power for the selected number of packs. Do not extrapolate the four-pack version’s charging peak to the one-pack version. If work changes over time, ask for written technical and commercial conditions for changing the configuration.
Auxiliary power versus energy
A 15 kW electric PTO does not necessarily consume 15 kWh every working hour. Ten minutes at that power demands 2.5 kWh before losses. Log equipment duty cycles and confirm which PTO the vehicle supports.
Choose the chassis before the battery
For an eDaily receiving a conversion, selection begins with the geometry of the job. Wheelbase is the distance between axles and affects available equipment length, turning space and mass distribution. Rear overhang is the distance from the rear axle to the vehicle end; heavy equipment far behind that axle increases its load and partially unloads the front. Adding a battery can change distribution and space available to the bodybuilder. Module choice should therefore use the exact variant’s drawing, not just a capacity table.
A simple example: a 400 kg tail lift whose centre of mass is 1 m behind the rear axle on a 4 m wheelbase adds about 500 kg to that axle and removes approximately 100 kg from the front in static equilibrium on level ground. Although total mass rises by 400 kg, the rear axle can be the limit. The actual calculation must include all equipment and cargo positions and the manufacturer’s limits.
Electric PTO in the daily energy balance
An electric power take-off (ePTO) lets compatible body equipment draw power through a vehicle interface instead of relying on an idling diesel engine. A tail lift or tipper may demand high power for short periods; refrigeration may draw lower average power for hours. Knowing maximum interface power is not enough: check voltage, continuous demand, peaks, protection and operating conditions authorised by Iveco and the bodybuilder.
If a workday includes 24 lifting cycles lasting 30 seconds at 12 kW, those cycles use 2.4 electrical kWh before losses. Refrigeration drawing 1.5 kW for six hours adds another 9 kWh. Separate these loads and compare them with traction energy to select module count. For special-purpose fleets, kWh per working hour or service may be a better additional indicator than kWh/100 km alone.